LOCTITE® TFX 3010
Features and Benefits
- Efficient heat transfer with a thermal conductivity of up to 3 W/mK, ensuring optimal thermal management.
- Cures at room temperature, offering easy and convenient application without the need for external heat.
- Outstanding dispensability for easy and precise application.
- Low compressive stress during installation, preserving the integrity of components and ensuring a secure fit.
- 12-month shelf life, solvent- and isocyanate-free for enhanced health & safety.
Documents and Downloads
Looking for a TDS or SDS in another language?
Technical Information
Number of components | 2 part |
Mixed | |
Colour, Mixed | Dark grey |
Cure type, Mixed | Room temperature (ambient) cure |
Mix ratio, by volume, Mixed | 1:1 |
Thermal conductivity, Mixed | 3.0 W/mK |
Work life, Mixed | 60.0 min. |
How to
Step by Step Guide
1. Remove residue
Using a plastic spatula (metal could damage the cooling plate), remove any remaining thermal gap filler from the cooling plate.
2. Clean cooling plate
Clean the cooling plate with TEROSON® VR 10 and a lint-free cloth.
3. Prepare cartridges
Open the LOCTITE® TFX 3010 thermal gap filler cartridges A+B by removing the lower cap and piercing the upper membrane. Connect them to the manifold. For faster dispensing, both cartridges can be preheated in the TEROSON® Cartridge Preheating Box at 60°C (for at least 15 minutes, up to a maximum of 60 minutes). Remove the lower cap before preheating.
4. Prepare application tool
Insert the cartridges into the LOCTITE® EQ HD 16 2C Pneumatic Dispenser and secure them using the locking mechanism.
5. Pre-dispense thermal gap filler
Gently squeeze the trigger and dispense a small amount of material, ensuring that both components A and B are dispensed evenly.
6. Attach mixer and dispense
Attach the static mixer to the dispenser and dispense approximately 5 cm of product before use to ensure even mixing of the two components.
7. Position the template
Position the OEM-specific application template on the cooling plate.
8. Apply thermal gap filler
Apply LOCTITE® TFX 3010 Thermal Gap Filler smoothly and evenly into the application template according to the OEM's instructions, keeping the tip of the static mixer embedded in the material to avoid trapping air.
9. Remove template
Carefully remove the application template from the battery tray and clean it using TEROSON® VR 10 and a lint-free cloth.
10. Re-assemble module
Place the battery module on the applied thermal gap filler within the 60-minute working time and press it evenly into its final position. Secure the module with the original fasteners. If you see gap filler at the edges of the battery module, you have applied sufficient force and the correct amount of material. Reconnect the electronics to the new battery module.